Programmable Transmitter PTM/Ex |
 |
 Programmable Transmitter PTM/Ex |
Features
- Pressure measuring range: 100 mbar … 1000 bar
- Adjustable 1:4 of the nominal range within -5% to +105%
- Accuracy: ≤ ± 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- Process temperature: -40 … 150°C
- Output signal: 4 … 20 mA
- Materials: Stainless steel, Titanium
|
Customer benefits
- Certificate: ATEX & EAC
- High flexibility due to scalalbe pressure range
- Adjustment of zero and span setting through software commands in the field
- Fast customization thanks to configurable product design
- Stainless steel and titanium version for use in acidic or otherwise aggressive media
|
Passive Transmitter TM/Ex |
 |
 Passive Transmitter TM/Ex |
Features
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 % FS
- Operating temperature: -40 … 125°C
- Process temperature: -40 … 150°C
- Output signal: mV
- Materials: Stainless steel, Titanium
|
Customer benefits
- Certificate: ATEX & EAC
- Great flexibility due to freely selectable pressure measuring range
- Readjustment of zero and span in the field
- Due to the modular structure, individual adaptation to the application
- Stainless steel and titanium version for use in acidic or otherwise aggressive media
|
Hygienic Pressure Transmitter ATM/F/Ex |
 |
 Hygienic Pressure Transmitter ATM/F/Ex |
Features
- Pressure measuring range: 100 mbar … 25 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- Process temperature: -25 … 100°C
- Output signal: 4 … 20 mA
- Materials: Stainless steel
|
Customer benefits
- Certificate: ATEX & EAC
- Welded and compact design for washdowns without residuals
- Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
- Demountable electrical connector option allow adjustment of zero and span setting in the field
- Fast customization thanks to configurable product design
- Short response times suitable for dynamic pressure measurements
|
High Precision Transmitter ATM.1ST/Ex |
 |
 High Precision Transmitter ATM.1ST/Ex |
Features
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.10 / 0.05 % FS
- Operating temperature: -40 … 125°C
- Process temperature: -40 … 150°C
- Output signal: 4 … 20 mA
- Total Error Band: ≤ ± 0.15 %FS (0…70 °C)
- Materials: Stainless steel, Titanium
|
Customer benefits
- Certificate: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Any measuring ranges between 0 … 50 mbar and 0 … 1000 bar available
- Static accuracies available to 0.05 %FS
- Hysteresis and repeatability better than 0.01 %
- Piezoresistive technology suitable for static and dynamic pressure measurements
- Modular design ideal for customization to the application
- Barometric or negative pressure ranges available
|
Analog Transmitter
with Temperature Compensation ATM.ECO/Ex |
 |
 Analog Transmitter
with Temperature Compensation ATM.ECO/Ex |
Features
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.2 % FS
- Operating temperature: -40 … 125°C
- Process temperature: -40 … 150°C
- Output signal: 4 … 20 mA
- Total Error Band: ≤ ± 0.3 %FS (0 … 70°C)
- Materials: Stainless steel
|
Customer benefits
- Certificate: ATEX, IECEx, EAC, GL/DNV, ABS, Lloyds
- Any measuring ranges between 0 … 100 mbar und 0 … 1000 bar available
- Static accuracy available of 0.2 % FS
- Hysteresis and repeatability better than 0.01 % FS
- Piezoresistive technology suitable for static and dynamic pressure measurements
- Modular design ideal for customization to the application
- Barometric or negative pressure ranges available
|
Analog Pressure Transmitter ATM/Ex |
 |
 Analog Pressure Transmitter ATM/Ex |
Features
- Pressure measuring range: 100 mbar … 1000 bar
- Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
- Operating temperature: -25 … 85°C
- Process temperature: -40 … 150°C
- Output signal: 4 … 20 mA
- Materials: Stainless steel, Titanium
|
Customer benefits
- Certificate: ATEX & EAC
- Fast customization thanks to configurable product design
- Demountable electrical connector option allow adjustment of zero and span setting in the field
- Compact design requires minimal space
- Short response times suitable for dynamic pressure measurements
|
|
|