Pressure Transmitters

Products > Pressure > Pressure Transmitters

We offer a comprehensive range of classic analog pressure transducers and transmitters to satisfy not only the process and test & measurement industry, but also any application where long cable lengths are required.

Select category:

Pressure Transmitter 4-20mA / 0-10V

General information

The analog pressure transmitters can be custom configured to a wide range of applications thanks to the eclectic selection of electrical and mechanical connections.

Miniature Transmitter ATM.mini

Miniature Transmitter ATM.mini

Features

  • Pressure measuring range: 1 … 100 bar
  • Accuracy: ≤ ± 0.2 / 0.1 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 125°C
  • Output signal: 0.5 … 4.5 VDC / 4 … 20 mA
  • Total Error Band: ≤ ± 0.5 %FS
  • Process connection: M8x1 M, M10x1 M, G 1/8 M, G 1/8 M, 1/8 NPT M, 3/8 - 24 UNJF-3A, 7/16 - 20 UNF
  • Materials: Stainless steel

Customer benefits

  • High accuracy over a wide temperature range
  • Customization thanks to a modular product design
  • No medium incompatibilities due to an all welded design
  • Miniature design for applications with space restrictions
Download datasheet
Analog Pressure Transmitter ATM

Analog Pressure Transmitter ATM

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Materials: Stainless steel, Titanium

Customer benefits

  • Fast customization thanks to configurable product design
  • Any measuring ranges between 0...100mbar and 0...1000bar available
  • Demountable electrical connector option to allow adjustment of zero and span setting in the field
  • Compact design requires minimal space
  • Short response time suitable for dynamic pressure measurements
Download datasheet
Analog Pressure Transmitter
with Temperature Compensation ATM.ECO

Analog Pressure Transmitter
with Temperature Compensation ATM.ECO

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Materials: Stainless steel

Customer benefits

  • Entry level series into precision pressure measurement
  • High measurement accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Any measuring ranges between 0...100mbar and 0...1000bar available
  • Fast customization thanks to configurable product design
  • Reverse polarity and short circuit protected, with integrated overvoltage protection
Download datasheet
Analog Pressure Transmitter
with Ceramic Measuring Cell ATM/K

Analog Pressure Transmitter
with Ceramic Measuring Cell ATM/K

Features

  • Pressure measuring range: 100 mbar … 20 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 125°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Corrosion and abrasion resistance for use in for example wastewater applications
  • Robust ceramic measuring cell results in long life time of the diaphragm
  • Fast customization thanks to configurable product design
  • Compact design requires minimal space
Download datasheet

High Precision Pressure Transmitter 4-20mA / 0-10V

General information

The ATM.1ST product line is an electronically compensated pressure transmitter providing an analog output. The transmitter offers accuracies of 0.05% FS including linearity, hysteresis, repeatability, zero and span setting errors.

High Precision Transmitter ATM.1ST

High Precision Transmitter ATM.1ST

Features

  • Pressure measuring range: 50 mbar … 1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 4 … 20 mA
  • Total Error Band: ≤ ± 0.15 %FS (0 … 70°C)
  • Process connection: G 1/4 F, 1/4 NPT, 1/2 NPT, G 1/4 M, G1/2 M
  • Materials: Stainless steel, Titanium

Customer benefits

  • Any measuring ranges between 0 … 50 mbar und 0 … 1000 bar available
  • Static accuracies available to 0.05 %FS
  • Hysteresis and repeatability better than 0.01 %
  • Piezoresistive technology suitable for static and dynamic pressure measurements
  • Modular design ideal for customization to the application
  • Barometric or negative pressure ranges available
Download datasheet

Intrinsically Safe Pressure Transmitter – FM/FMc Certified

General information

STS offers a comprehensive range of classic 2-wire 4-20mA output transducers and transmitters for use in hazardous environments. Certifications include FM and FM-C.

Analog Pressure Transmitter ATM/IS

Analog Pressure Transmitter ATM/IS

Features

  • Pressure measuring range: 100 mbar … 690 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: FM & FM-C
  • Fast customization thanks to configurable product design
  • Demountable electrical connector option allow adjustment of zero and span setting
  • Compact design requires minimal space
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Analog Transmitter
with Temperature Compensation ATM.ECO/IS

Analog Transmitter
with Temperature Compensation ATM.ECO/IS

Features

  • Pressure measuring range: 100 mbar … 690 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
  • Materials: Stainless steel

Customer benefits

  • Certificate: FM, FM-C & IECEx & ATEX
  • Entry level series into precision pressure measurement
  • High accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Fast customization thanks to configurable product design
  • Reverse polarity and short circuit protected, with integrated overvoltage protection
Download datasheet
High Precision Transmitter ATM.1ST/IS

High Precision Transmitter ATM.1ST/IS

Features

  • Pressure measuring range: 100 mbar … 690 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: FM, FM-C, IECEx & ATEX
  • High accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
  • Short response times suitable for dynamic pressure measurements
  • Fast customization thanks to configurable product design
  • Reverse polarity and short circuit protected, with integrated overvoltage protection
Download datasheet
Hygienic Pressure Transmitter ATM/F/IS

Hygienic Pressure Transmitter ATM/F/IS

Features

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -25 … 100°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Certificate: FM & FM-C
  • Welded and compact design for washdowns without residuals
  • Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet

Intrinsically Safe Pressure Transmitter – ATEX / IECEx Certified

General information

2-wire 4-20mA output transducers and transmitters for use in intrinsically safe applications. This section provides an overview of ATEX and IECEx certified products.

Analog Pressure Transmitter ATM/Ex

Analog Pressure Transmitter ATM/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX & EAC
  • Fast customization thanks to configurable product design
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Compact design requires minimal space
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Analog Transmitter
with Temperature Compensation ATM.ECO/Ex

Analog Transmitter
with Temperature Compensation ATM.ECO/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0 … 70°C)
  • Materials: Stainless steel

Customer benefits

  • Certificate: ATEX, IECEx & EAC
  • Entry level series into precision pressure measurement
  • High accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Fast customization thanks to configurable product design
  • Reverse polarity and short circuit protected, with integrated overvoltage protection
Download datasheet
High Precision Transmitter ATM.1ST/Ex

High Precision Transmitter ATM.1ST/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX, IECEx & EAC
  • High measurement accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
  • Short response times suitable for dynamic pressure measurements
  • Fast customization thanks to configurable product design
  • Reverse polarity and short circuit protected, with integrated overvoltage protection
Download datasheet
Hygienic Pressure Transmitter ATM/F/Ex

Hygienic Pressure Transmitter ATM/F/Ex

Features

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -25 … 100°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Certificate: ATEX & EAC
  • Welded and compact design for washdowns without residuals
  • Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Passive Transmitter TM/Ex

Passive Transmitter TM/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX & EAC
  • Unreinforced output signal
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Programmable Transmitter PTM/Ex

Programmable Transmitter PTM/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX & EAC
  • High flexibility due to scalalbe pressure range
  • Adjustment of zero and span setting through software commands in the field
  • Fast customization thanks to configurable product design
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
Download datasheet

Fieldbus & Digital Pressure Transmitter

General information

This product family offers both digital output pressure transmitters with interfaces such as RS485, Modbus protocol and combination analog/digital output versions.

Modbus Transmitter DTM.OCS.S

Modbus Transmitter DTM.OCS.S

Features

  • Pressure measuring range: 200 mbar…100 bar
  • Accuracy: ≤ ± 0.15 / 0.05 / 0.03 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -40…85 °C
  • Interface: RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • High precision digital pressure sensor with standard Modbus interface
  • Fast customization thanks to modular product design
  • High measurement accuracy is ensured by sophisticated digital temperature compensation algorithms
  • Adjustment of zero and span setting through Modbus commands
Download datasheet
Programmable Transmitter PTM/RS485

Programmable Transmitter PTM/RS485

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25 … 85°C
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • 2 Output signals (p & T): 4 … 20 mA
  • Interface: RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • High flexibility due to scalalbe pressure range
  • Digital (RS485) and analogue (4-20mA) output signal in one sensor
  • Available as multi-parameter sensor (pressure & temperature)
  • Fast customization thanks to modular product design
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
Download datasheet

Programmable Pressure Transmitter

General information

STS offers rangeable transmitters where the process pressure might change and maximum output resolution is required, or to standardize on a single type of device to satisfy a multiple number of installations. These are generally programmable through a digital interface such as RS485.

Programmable Transmitter PTM/Ex

Programmable Transmitter PTM/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX & EAC
  • High flexibility due to scalalbe pressure range
  • Adjustment of zero and span setting through software commands in the field
  • Fast customization thanks to configurable product design
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
Download datasheet
Programmable Transmitter PTM/RS485

Programmable Transmitter PTM/RS485

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25 … 85°C
  • Operating temperature: -25 … 85°C
  • Process temperature: -40 … 150°C
  • 2 Output signals (p & T): 4 … 20 mA
  • Interface: RS485
  • Materials: Stainless steel, Titanium

Customer benefits

  • High flexibility due to scalalbe pressure range
  • Digital (RS485) and analogue (4-20mA) output signal in one sensor
  • Available as multi-parameter sensor (pressure & temperature)
  • Fast customization thanks to modular product design
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
Download datasheet
Pressure Transmitter 4-20mA PTM

Pressure Transmitter 4-20mA PTM

Features

  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable: 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium

Customer benefits

  • High flexibility due to scalalbe pressure range
  • Adjustment of zero and span setting through software commands
  • Fast customization thanks to modular product design
  • Stainless steel and titanium version for use in acidic or otherwise aggressive media
Download datasheet

Passive Transmitter (mV)

General information

This series of pressure transducers and transmitters provide a millivolt (mV) output of up to 15 mV/V for use in applications where it is preferred to remove the electronics from the measuring location or the user already has his own characterization capability.

Passive Transmitter TM/Ex

Passive Transmitter TM/Ex

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Certificate: ATEX & EAC
  • Unreinforced output signal
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Passive Transmitter TM

Passive Transmitter TM

Features

  • Pressure measuring range: 100 mbar … 1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40 … 125°C
  • Process temperature: -40 … 150°C
  • Output signal: mV
  • Materials: Stainless steel, Titanium

Customer benefits

  • Fast customization thanks to modular product design
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Very short response times suitable for dynamic pressure measurements
Download datasheet

Hygienic Pressure Transmitter

General information

This pressure sensor product family developed and produced by STS are suitable for pressure monitoring and are specifically designed to meet the requirements of the food, beverage and life sciences industries. Our products meet the demanding expectations of accuracy, reliability, and cleanability.

Hygienic Pressure Transmitter ATM/F/IS

Hygienic Pressure Transmitter ATM/F/IS

Features

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -25 … 100°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Certificate: FM & FM-C
  • Welded and compact design for washdowns without residuals
  • Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Hygienic Pressure Transmitter ATM/F/Ex

Hygienic Pressure Transmitter ATM/F/Ex

Features

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -25 … 100°C
  • Output signal: 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Certificate: ATEX & EAC
  • Welded and compact design for washdowns without residuals
  • Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Fast customization thanks to configurable product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet
Hygienic Pressure Transmitter ATM/F

Hygienic Pressure Transmitter ATM/F

Features

  • Pressure measuring range: 100 mbar … 25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25 … 85°C
  • Process temperature: -25 … 100°C
  • Output signal: 0 … 5 / 0 … 10 VDC, 0 … 20 / 4 … 20 mA
  • Materials: Stainless steel

Customer benefits

  • Welded and compact design for washdowns without residuals
  • Surface roughness of flush process connection Ra ≤ 0.4 for highest hygienic standards
  • Demountable electrical connector option allow adjustment of zero and span setting in the field
  • Fast customization thanks to modular product design
  • Short response times suitable for dynamic pressure measurements
Download datasheet

Copyright © 2019 Sensors AS - All Rights Reserved
|HOME| |PRODUCTS| |HYDROPOWER| |NEWS| |CONTACT|
---
Sensors AS | Setersletta 3 | 2006 Løvenstad | Norway | Phone: +47 67 90 43 00 | Org. nr. NO 982 517 346 MVA